Figure 7

Figure 7 - Calculated phase of the dector signal, when located underneath the plate. Exciter at 50 mm (2 in.) distance, carrying 300 mA at 200 Hz.

 [ Back to March '97 NDT Solution ]

 

Figure 8

Figure 8 - Calculated influence of frequency on detector signal when detector is directly beneath the plate. The exciter carries 300 mA at 200 Hz and is at 50 mm (2 in.) from plate center. Exciter-detector spacing is 50 mm (2 in.).

[ Back to March '97 NDT Solution ]

 

Figure 9

Figure 9 - Experimental depth gaging of full circumferential grooves under 6.34 mm (0.25 in.) thick support plate. Detector is centered under plate. Exciter-dector spacing is 50 mm (2 in.) and I= 300 mA.

[ Back to March '97 NDT Solution ]

Copyright © 1997 by the American Society for Nondestructive Testing, Inc. All rights reserved.

 

 


 
Copyright © 2008 by the American Society for Nondestructive Testing, Inc. ASNT is not responsible for the authenticity or accuracy of information herein. Published opinions and statements do not necessarily reflect the opinion of ASNT. Products or services that are advertised or mentioned do not carry the endorsement or recommendation of ASNT.

IRRSP, NDT Handbook, The NDT Technician and www.asnt.org are trademarks of the American Society for Nondestructive Testing, Inc. ACCP, ASNT, Level III Study Guide, Materials Evaluation, Nondestructive Testing Handbook, Research in Nondestructive Evaluation and RNDE are registered trademarks of the American Society for Nondestructive Testing, Inc.

ASNT exists to create a safer world by promoting the profession and technologies of nondestructive testing.