The American Society for Nondestructive Testing   
Members Only | Contact Us | ShopASNT | Search   

NDT Solution

Pipe Inspection by Infrared Thermography

Figure 1-2

 

Figure 1

Figure 1 - Pulsed active infrared thermography (PAIRT).

 [ Back to September '99 NDT Solution ]

 

 

Figure 2

Figure 2 - PAIRT method in transmission. Schematic diagram and picture of the apparatus used to assess wall losses in pipes.

 [ Back to September '99 NDT Solution ]

 

Copyright © 1999 by the American Society for Nondestructive Testing, Inc. All rights reserved.

[ Materials Evaluation ]

 

 
Copyright © 2008 by the American Society for Nondestructive Testing, Inc. ASNT is not responsible for the authenticity or accuracy of information herein. Published opinions and statements do not necessarily reflect the opinion of ASNT. Products or services that are advertised or mentioned do not carry the endorsement or recommendation of ASNT.

IRRSP, NDT Handbook, The NDT Technician and www.asnt.org are trademarks of the American Society for Nondestructive Testing, Inc. ACCP, ASNT, Level III Study Guide, Materials Evaluation, Nondestructive Testing Handbook, Research in Nondestructive Evaluation and RNDE are registered trademarks of the American Society for Nondestructive Testing, Inc.

ASNT exists to create a safer world by promoting the profession and technologies of nondestructive testing.